Welcome to GRGTEST!
Service Hotline 400-602-0999
Your Industry Rail Transit Preventive Test of Electric Power Safety Tools and Instruments
Preventive Test of Electric Power Safety Tools and Instruments
We provide testing service for the preventive test of electric power safety tools and instruments, including insulation, climbing and individual protection
Service Introduction
Enterprises should always put the safety production of electric power first. In order to standardize the management of safety tools and instruments in the power industry, providing safe, reliable and practical safety tools and instruments in the daily using to protect the health and safety of power system workers is regarded as the first priority of enterprise safety production and operation management. Electric power safety tools and instruments are materials, instruments and devices to prevent electric shock, mechanical injury, falling from height and other injuries and occupational hazards of electric power operators when they are in the field operation such as maintenance, overhaul, test and construction of the power system. The preventive test of electric power safety tools and instruments means the inspection, test or detection in order to find the hidden dangers in the process of using electric power safety tools and instruments, and to prevent equipment or personal accidents. 

Product Scope: 

Insulating gloves, insulating boots (shoes), electroscopes, insulating rods, portable short circuit ground wires, safety belts in electrician operation, climbers, climbing boards used in rail transit. 

Relevant Qualifications: 

CNAS, CMA and Grade V test-takers. 

Test Cycle: 

5 working days. 

Test Items (Part): 

The main test standards and test basis: 
1. DL/T 1476-2015 Preventive Test Code of Electric Safety Tools and Devices 
2. DL/T 976-2017 Preventive Test Code of Tools, Devices and Equipment for Live Working 
3. GB 26859-2011 Safety Code of Electric Power Industry - Part of Electric Lines 
4. Q/CSG 510001-2015 China Southern Power Grid Company Limited Working Regulations of Power Safety 
5. Q/GDW 1799.2-2013 Working Regulation of Power Safety (Transmission Line Section) 
6. DL/T 1741-2017 Preventive Test Code of Small Construction Machines and Tools for Electrical Engineering 
Product Type Model and Specification Test Item
Insulating gloves High and low voltage, 0.38kV, 10kV, 20kV, 35kV Power frequency withstand voltage test
Insulating boots Auxiliary model, 3kV, 10kV, 20kV, 35kV Power frequency withstand voltage test
DC insulating rod/discharging rod DC1.5kV DC voltage withstand test
Insulating rods (operating rods, link rods, brake pull-rods, height measuring rods, grounding rods, phase detector insulating rods, etc.) AC10kVAC35kVAC110kVAC220kVAC500kV Power frequency withstand voltage test
DC electroscope DC1.5kV DC voltage withstand test and starting voltage test
Capacitive type electroscope AC10kVAC35kVAC110kVAC220kVAC500kV Power frequency withstand voltage test and starting voltage test
DC grounding wires (including insulating rods and grounding wires) DC1.5kV DC voltage withstand test and DC resistance test
Portable short circuit ground wires (including insulating rods and grounding wires) AC10kVAC35kVAC110kVAC220kVAC500kV Power frequency withstand voltage test and DC resistance test
Insulation rubber pad High and low voltage Power frequency withstand voltage test
Safety belt Falling suspension Static load test
Pole operation
Regional restriction
Safety strap / Static load test
Climbing board / Static load test
Climber / Static load test
Differential speed control device / No-load test
Falling protector / Static load test and drop test
Buffer / Static load test and impact test
Safety helmet Ordinary type Puncture resistance test and impact performance test
Construction tools and instruments (wire grips, wire clamps, double hooks, hoists, hoisting belts, pulley, shackles, etc.) Test tensile force range: 0-500kN Static test
Rope tools (wire rope, manila rope, fiber rope, insulating rope, nylon rope, etc.) Test tensile force range: 0-500kN Static test
Assembly of strain clamp, splicing sleeve and stranded wire / Grip strength test
Bamboo ladder / Static load test
Aluminum alloy ladder / Static load test
Personal security wire (grounding soft copper wire) / DC resistance test
Insulating cell 10kV35kV Power frequency withstand voltage test and surface power-frequency voltage-withstand test
Insulating ladder AC10kVAC35kVAC110kVAC220kVAC500kV Power frequency withstand voltage test and static load test
Insulating rope AC10kVAC35kVAC110kVAC220kVAC500kV Power frequency withstand voltage test and static load test
Insulating safety helmet / Power frequency withstand voltage test
Insulating clothes 0.38kV10kV20kV35kV Power frequency withstand voltage test
Insulating pants 0.38kV10kV20kV35kV Power frequency withstand voltage test
Insulating shawls 0.38kV10kV20kV35kV Power frequency withstand voltage test
Insulating sleeves 0.38kV10kV20kV35kV Power frequency withstand voltage test
Insulating blankets 0.38kV10kV20kV35kV Power frequency withstand voltage test
Insulating pad 0.38kV10kV20kV35kV Power frequency withstand voltage test
Insulating protective cover 0.38kV10kV20kV35kV Power frequency withstand voltage test
Insulating block / Power frequency withstand voltage test
Insulating wire grips / Power frequency withstand voltage test
Car with insulated bucket arm 10kV35kV AC voltage withstand test, leakage current test and rated load full working condition test
Insulating platform (scaffold) 10kV Power frequency withstand voltage test and platform strength test
Insulating shielding clothing / Garment (including shoes and socks) resistance test, and shielding efficiency test of whole clothing
Electrostatic protective clothing / Shielding efficiency test